PRT-11Product ship smoke
What this test proves
The product team's own end-to-end smoke of the obfuscated ship build with a valid license, run on the exact build under test.
How it is tested
- Publish the service plainly (not obfuscated) from the exported source, for the name check
- Run the product's ship smoke test against this run's QA service folder
- Pass if it exits 0 (every step passed); nothing machine-wide is used (the script checks it)
Results
| Column | Expected | Result | Detail | Time |
|---|---|---|---|---|
| Build, QA key | Works | Pass |
exit code 0
PASS trial record write and read (temporary stores only): 7 days
PASS update check answer (signed by the QA key) is parsed: Version 9.9.9 is available (installed: 0.1.0).
PASS obfuscated service starts with the valid license and serves the obfuscated admin client: listening on 60815
PASS pipe: license status is Active: PrologicSign PACS Enterprise
PASS pipe: check-in through the service: The license server confirmed the license.
PASS pipe: online activation through the service: PrologicSign PACS Enterprise, licensed to Ship smoke test (QA). Valid until 27 Nov 2026.
PASS pipe: settings reload, destinations and audit: 0 destinations, 4 audit rows
PASS service log has no serialization error: clean
PASS the installed DicomKit license on the test PC is untouched
PASS no machine-wide trial was started
16 passed, 0 failed
|
1817.9 s |
Test run
- Build
- PrologicSign PACS 0.1.0 ship build (bfd61b5): Release, obfuscated, strong-named
- Run
- ba7cd839-7956-4ab5-8e58-8e1444c7baf4
- Started (UTC)
- 2026-10-28 06:56:57, finished 08:49:12
This report is not complete: see why rows are pending.